1. Direct Client Ownership
In an on-premises deployment, the hardware is bought and owned by your business. It belongs on your fixed-asset register, not ours. You retain the on-site hardware if the support engagement ends.
Software licences, administrative access, required dependencies and the handover arrangements are documented for the selected system, and the document store remains on your drives.
Asset Integrity & Manufacturer Warranties
Systems are specified on Dell PowerEdge, Supermicro or HPE platforms, with the manufacturer's on-site warranty where the chosen model and your region offer one. A failed PSU, DIMM, drive or motherboard is then a field-engineer visit under that warranty rather than a parcel back to us. The exact coverage is confirmed in the specification you are quoted.
2. Chassis & Form Factors
The following are illustrative configuration categories, not orderable server models. Chassis dimensions, rails, GPU support, power limits and warranty coverage are confirmed in the quoted bill of materials. Which shape fits depends on the rack depth you have, the power and cooling in the room, and how close it sits to people's desks.
| Specification | 2U Compact Enterprise Chassis | 4U High-Density Rack Unit |
|---|---|---|
| Deployment Target | Office comms rooms, wall-mount cabinets, or branch offices with standard depth racks. | Dedicated server rooms, central data centres, or facilities with dedicated HVAC cooling. |
| GPU Density | Up to 2x dual-slot PCIe Gen 5 accelerators. | Up to 4x dual-slot PCIe accelerators or 4-way NVLink baseboards. |
| Thermal Output | Up to about 1,000W at peak; low-noise enterprise fan profiles available. | Up to about 1,600W at peak; high-velocity redundant blower modules. |
| Concurrency | Depends on model, context length and request mix; measured on the agreed workload in the pilot. | Depends on model, context length and request mix; measured on the agreed workload in the pilot. |
| Physical Dimensions | Height: 88.9 mm (2U) • Typical depth: 650–720 mm. Check chassis length, rail adjustment range, rear cabling and cabinet clearance for the selected model. | Height: 177.8 mm (4U) • Typical depth: 760–840 mm. Check chassis length, rail adjustment range, rear cabling and cabinet clearance for the selected model. |
2U Compact Chassis (Branch & Office Closets)
Most firms in leased offices — a city centre floor or a regional business park — have a comms cabinet rather than a server room, and a 2U chassis is the usual starting point for one. Rack fit, operating noise and thermal limits are checked for the selected chassis and room before installation.
4U High-Density Rack Unit (Industrial & Corporate)
For engineering firms, high-volume legal practices, or anyone with a proper server room, the 4U chassis takes four GPUs, more airflow per card, and more DIMM slots. That is what you need to run large models while re-indexing a big archive in the background.
3. GPU Accelerators & VRAM Sizing
Two numbers decide which models you can run and how fast: how much GPU memory (VRAM) you have, and how quickly the card can read it. The model weights and every active user's context have to fit in VRAM at the same time. We fit data-centre accelerators with ECC VRAM, passively or actively cooled to suit the chassis.
- 48GB VRAM (dual 24GB or single 48GB PCIe): Typical baseline for quantised dense models from 14B to 32B parameters (e.g. Qwen 2.5 32B, Mistral Small), for cited drafting and search. Concurrency, prompt lengths and KV cache usage vary by workflow, so capacity is measured in the pilot.
- 96GB to 128GB VRAM (dual 48GB or quad PCIe): Sized for 70B-class models at 4- or 8-bit quantization. Allows role splitting: one card serves interactive queries while the other processes background document OCR and vector embeddings.
- 192GB aggregate VRAM (four 48GB cards): High-capacity allocation running 70B models at full 16-bit precision (~140GB weights), leaving space for extended KV cache contexts (up to 32k–64k tokens) and concurrent ingestion tasks. Interconnect and model-placement support depend on the selected cards and runtime.
We do not fit consumer gaming cards. Data-centre cards carry ECC VRAM, which provides detection and correction for supported classes of memory errors; it does not verify the factual correctness of a generated answer. They report temperature and faults to the server's management controller (iDRAC, iLO or IPMI), and they are rated for continuous full load around the clock.
4. Local NVMe Storage & ECC System Memory
Once the index is built, each query is served mostly from RAM, so storage speed matters less than people expect. It matters at ingestion and re-indexing, when tens of thousands of pages are parsed, embedded and written in one go. Slow disks turn an overnight re-index into a weekend job.
High-Speed Enterprise NVMe Arrays
The specification uses direct-attached PCIe 5.0 enterprise NVMe drives, mirrored (RAID-1) or striped mirrors (RAID-10):
- Index volume: A dedicated NVMe namespace holds the vector index (Qdrant or pgvector) and the SQLite metadata store. Enterprise drives in this class are quoted around 7,000 MB/s sequential read and 1,000,000 random-read IOPS; the figures are confirmed for the part specified.
- Encrypted document store: Self-encrypting drives (TCG Opal 2.0) with LUKS2 on top hold the parsed documents, full-text index and extracted PDF text. The encryption and key-unlock design is selected to protect data at rest, including the risk of removed drives.
System ECC Registered DDR5 Memory
Servers ship with 128GB to 512GB of registered ECC DDR5. RAM is sized for the expected indexes and serving workload, so the index and metadata are meant to stay in memory rather than being read from disk on each query. The pilot checks memory pressure, storage access and performance under representative load.
5. Power Draw, Cooling & Noise Planning
A GPU server in an office is a heater with fans. During the paid on-site assessment we measure your electrical supply and the room it will sit in before we specify anything.
- Electrical Load: Normal idle draw ranges between 150W and 250W. Under full concurrent inference load, draw reaches 750W (2U single/dual GPU) to 1,600W (4U quad GPU). All systems include dual redundant, titanium-rated hot-swap power supplies configured for dual-circuit distribution.
- Heat Dissipation: A 1,000W server produces approximately 3,412 BTU/hr of heat. In an unventilated closet, ambient temperature can exceed the server's permitted intake range. We calculate your comms room volume and check whether existing extract ventilation or split-system AC is adequate.
- Acoustics: Server fans run at variable RPM. Noise suitability is assessed for the room and adjacent workspaces. Acoustic treatment or a different location may be needed.
6. Dedicated Hosted Private AI Option
If you have no comms room, or your team works across co-working spaces, the server can be hosted for you instead. It is one bare-metal machine assigned to your business alone, in a facility and location agreed with you before deployment.